4-17
Main menu
Explanation
Default
Sub-menu1
Sub-menu2
Sub-menu3
DEPTH
An alarm occurs when the water depth matches the
set parameters.
【Over, Under, In range, Out range, OFF】
OFF
WIND
An alarm occurs when the wind velocity matches the
set parameters.
【 Over, OFF 】
OFF
AIR TEMP
An alarm occurs when the air temperature matches
the set parameters.
【Over, Under, In range, Out range, OFF】
OFF
PRESSURE An alarm occurs when the atmosphere matches the
set parameters.
【Over, Under, In range, Out range, OFF】
OFF
HUMIDITY
An alarm occurs when the humidity matches the set
parameters.
【Over, Under, In range, Out range, OFF】
OFF
5> BEACON
DISPLAY
Display the beacon information 【 ON, OFF 】
ON
6> DAISY CHAIN
To start the daisy chain function, set "DAISY CHAIN" to
"ON".
・The display can be connected up to 3 units.
OFF
7> INTERFACE
DATA I/O
DATA IN/OUT1,2,3
Select the output format. 【 NMEA, IEC 】
NMEA
DATA IN/OUT
Select the port to "SEND" or "RECEIVE".
・When the port is set for output, output sentence and
output interval can be selected.
・When the NMEA format is set, output NMEA version
can be selected.
【NMEA version:1.5, 2.1, 2.3, 4.0 】
RECE-
IVE
BIT RATE
Select the bit rate.
【 4800, 9600, 19200, 38400bps 】
4800
DATA IN/OUT4
Select the output format. 【 NMEA, IEC 】
NMEA
SENTENCE
(VERSION)
Select the output sentence and interval.
・When the NMEA format is set, output NMEA version
can be selected.
【NMEA version:1.5, 2.1, 2.3, 4.0 】
Ver1.5
BIT RATE
Select the bit rate.
【 4800, 9600, 19200, 38400bps 】
4800
RS-485
Select the output format. 【 NMEA, IEC 】
IEC
SENTENCE
(VERSION)
Select the output sentence and interval.
・When the NMEA format is set, output NMEA version
can be selected.
【NMEA version:1.5, 2.1, 2.3, 4.0 】
-
BIT RATE
Select the bit rate.
【 38400, 57600, 76800, 115200bps 】
115200
CONTACT INPUT
Selectting a contact input port. 【 DIMMER、ACK 】
ACK