– 22 –
5-16 Adjusting the presser bar height
Remove the frame cover.
Adjustment procedure
1. Assemble the standard presser foot in the presser foot holder. Raise the presser foot lifting lever.
2. Loosen the setscrew of the presser bar position bracket. Adjust the distance from the top surface of the
throat plate to the bottom face of the standard presser foot to 6±0.3 mm. At this time, check the direction
of the presser bar so that the standard presser foot is in parallel to the feed dog groove and so that the
needle hole in the throat plate is nearly aligned with the slot in the standard presser foot.
5-17 Motor belt
Remove the front panel.
Adjustment procedure
1. Set the motor timing belt to the motor pulley and the motor shaft pulley.
2. Adjust the motor bracket so that the belt deection amount becomes 6±1 mm when pressing the center of
the belt with a force of 0.98 N. After completion of adjustment, tighten the setscrew in the motor bracket.
6 ± 0.3 mm
Setscrew of
the presser bar
position bracket
Motor pulley
Motor shaft pulley
Motor bracket
Setscrew of the motor bracket
Setscrew of the motor bracket
0.98 N
6 ± 1 mm

Other manuals for JUKI HZL-F series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI HZL-F series and is the answer not in the manual?

JUKI HZL-F series Specifications

General IconGeneral
BrandJUKI
ModelHZL-F series
CategorySewing Machine
LanguageEnglish

Related product manuals