EasyManua.ls Logo

JUKI MS-1261M - 11. ADJUSTING THE NEEDLE GUARD; Needle Guard Clearance Adjustment; Vertical Position of Needle Guard; Needle and Looper Clearance Adjustment

JUKI MS-1261M
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 6 –
ENGLISH
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the following
work after turning the power off and ascertaining that the motor is at rest.
11. ADJUSTING THE NEEDLE GUARD
(
0.05 to 0.1 mm for MS-1261M
)
0.1 to 0.2 mm
0.1 to
0.2mm
(MS-1261)
0.05 to
0.1mm
(MS-1261M)
WARNING :
To protect against possible personal injury due to abrupt start of the machine, be sure to start the following
work after turning the power off and ascertaining that the motor is at rest.
12. ADJUSTING THE LOOPER LHREAD CAM