EasyManua.ls Logo

JUKI SC-510 - Page 45

JUKI SC-510
45 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
– 43 –
No. Description of error detected Cause of occurrence expected Items to be checked
E799 Thread trimming sequence
time over
Thread trimming sequence control is not
completed within the predetermined time
(3 seconds).
The machine head mounted is dif
ferent
from the selection of the machine head.
Motor pulley diameter is different from the setting
of motor pulley diameter effective diameter).
Belt is loose.
E811 Overvoltage When voltage higher than guaranteed one
is inputted.
220V has been inputted to SC-510 of
1
10V specications.
4
00V is applied to the box of 220V (230V).
• Check whether the applied power voltage is
higher than the rated voltage + (plus)
1
0%
or more.
• Check whether 110V/220V changeover
switch is improperly set.
In the aforementioned cases, POWER p.c.b
is broken.
E813 Low voltage When voltage lower than guaranteed one
is inputted.
1
10V has been inputted to SC-510 of
220V specications.
110V is applied to the box of 220V.
Inner circuit is broken by the applied over
-
voltage
Check whether the voltage is lower than
the rated voltage – (minus)
10% or less.
• Check whether 110V/220V changeover
switch is improperly set.
Check whether fuse or regenerative resis
-
tance is broken.
E906
Operation panel transmis-
sion failure
Disconnection of operation panel cord.
Operation panel has broken.
Check the operation panel connector
(CN38) for loose connection and discon-
nection.
Check whether the operation panel cord
has broken since the cord is caught in the
machine head.
E924 Motor driver failure Motor driver has broken.