JUKI SC-922 - 11. Setting of the auto lifter function

JUKI SC-922
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 46 –
42 7 0
52 1 0
Pedal depressing speed limiting function (Function setting No. 242)
The function limits the sewing speed upon the optical sensor input.
(Caution) This function can be set to "3" only for the CP-18. For the other operation panels, set this
function with the switches on the panel.
0 : The function is disabled.
1 : Fixed at the one-shot speed
2 : Limited to the one-shot speed
3 : When the optical sensor is enabled, the sewing machine runs under the
automatic mode upon depress on the pedal.
Optical sensor thread-trimming prohibiting function (Function setting No. 247)
Thread trimming activated by the optical sensor input is prohibited.
(Caution) This function can be set only for the CP-18. For the other operation panels, set this function
with the switches on the panel.
0 : Thread trimming is enabled
1 : Thread trimming is disabled (solenoid output is prohibited)
Optical sensor input logic changeover (Function setting No. 251)
In the case two or more optical sensors are used, the input retrieving method is selected.
0 : OR input
1 : AND input
42 2 0

Other manuals for JUKI SC-922