Optical sensor function (Function setting Nos. 235, 236, 237, 238, 239, 242, 247 and 251)
Optical sensor function (Function setting No. 235)
Enable this function if it is to be used.
Before enabling this function, assign the optical sensor input with No. 12.
(Caution) This function is enabled only for the CP-18. For the other operation panels, set the optical
sensor with the switches on the panel.
0 : Optical sensor function is disabled
1 : Optical sensor function is enabled
Optical sensor lter function (Function setting No. 236)
This function lters the optical sensor input.
Use this function in combination with Function No. 237: Number of stitches for optical sensor lter.
0 : Optical sensor lter function is disabled
1 : Optical sensor lter function is enabled
Numbers of stitches for optical sensor lter (Function setting No. 237)
The number of stitches for which the optical sensor input is ltered is set.
It is used when Function No. 236: Number of stitches for optical sensor lter is enabled.
0 to 99 stitches
Number of stitches for stopping the sewing machine after optical sensor input (Function setting No. 238)
The number of stitches to be sewn from the optical sensor input to the stop of the sewing machine is set.
(Caution) This function is enabled only for the CP-18. For the other operation panels, set the number of
stitches for stopping the sewing machine after optical sensor input with the switches on the panel.
0 to 99 stitches
Number of times of optical sensor detection (Function setting No. 239)
The sewing machine carries out automatic thread trimming when the set number of times the optical sen-
sor input is turned ON is reached.
1 to 15 times
32 5 0
32 6 0
$4
Bobbin thread remaining amount detecting function (function setting Nos. 167 and 168)
Enable/disable of the bobbin thread remaining amount detecting function (function setting No. 167)
Enable/disable of the bobbin thread remaining amount detecting function is set in the case the bobbin
thread remaining amount detecting device is used.
0 : Disabled
1 : Enabled
Bobbin thread remaining amount detecting function (function setting No. 168)
Refer to the Instruction Manual for the device for details about the setting.
32 7 0
Direction of sewing
Sensor signal
Sensor input
No.237
32 8 0
32 9 1