Hangzhou Junce Instruments Co., Ltd.
value is greater than 0.00V, the protection will be activated. If the current
voltage is less than the set low voltage protection value, the upper right of the
APP main interface will display LVP, which is in the protection state.
It is necessary to purchase a relay to realize the protection function,
and the relay can be installed in the circuit to protect the circuit from
being disconnected.
3 Discharge overcurrent protection
Click the OCP Negative Overcurrent Protection button to pop out the
“Input Discharge Overcurrent Protection” pop-up box, enter the corresponding
value and click OK to complete the modification, as shown in Figure 3-1-24
below.
When the value is 0.00A, the protection function will not be activated. If
the value is greater than 0.00A, the protection function will be activated. If the
current discharge current is greater than the set discharge overcurrent
protection value, OCP will be displayed on the upper right of the main interface
of the APP, which is in the protection state.
The protection function needs to purchase additional relays, and only after
installing the relays in the circuit can it play a protective role in disconnecting
the circuit.
4 Over temperature protection
Click the OTP over temperature protection button, the "Input:External over
temperature protection" pop-up box will pop out, enter the corresponding value,
and click OK to complete the modification, as shown in Figure 3-1-25 below.
When the value is 0°C, the protection function will not be activated, if the
value is greater than 0°C, the protection will be activated. If the current
ambient temperature exceeds the set over-temperature protection value, the
OTP will be displayed on the upper right of the main interface of the APP,
which is in the protection state.
It is necessary to purchase a relay to realize the protection function,
and the relay can be installed in the circuit to protect the circuit from
being disconnected.
5 Over current protection
Click the OCP over current protection button, the "Input:Positive over
current protection" pop-up box will pop out, enter the corresponding value, and
click OK to complete the modification, as shown in Figure 3-1-26 below.
When the value is 0.00A, the protection function will not be activated. If
the value is greater than 0.00A, the protection will be activated. If the current
discharge current is greater than the set discharge over-current protection
value,OCP will be displayed on the upper right of the APP main interface,
which is in the protection state.
It is necessary to purchase a relay to realize the protection function,
and the relay can be installed in the circuit to protect the circuit from
being disconnected.
6 Over power protection