Click the NCP charging overcurrent protection button to pop out the "Input
charging overcurrent protection" pop-up box, enter the corresponding value
and click OK to complete the modification, as shown in Figure 3-1-27 below.
When the value is 0.00A, the protection function will not be activated. If
the value is greater than 0.00A, the protection will be activated. If the current
discharge current is greater than the set discharge overcurrent protection
value, NCP will be displayed on the upper right of the main interface of the APP,
which is in the protection state.
It is necessary to purchase a relay to realize the protection function,
and the relay can be installed in the circuit to protect the circuit from
being disconnected.
7 Low temperature protection
Click on the low temperature protection to pop up the "low temperature
protection pop-up" pop-up box, you can choose to turn on or off the low
temperature protection, click on the open pop-up box "input low temperature
protection (-20-20) ", enter the corresponding value and click OK to
complete the modification. The low temperature protection function is not
activated by default. When we set the low temperature protection value to 0 °C,
if the value is less than 0 °C, the protection will be activated, and the upper
right of the APP main interface will display LTP, which is in the protection state.
As shown in Figure 3-1-28 and Figure 3-1-29 below.
8 Protection recovery time
Click the protection recovery time button to pop out the "Enter protection
recovery time" pop-up box, enter the corresponding value and click OK to
complete the modification, as shown in Figure 3-1-30 below.
9 Delay protection time
Click the delay time button to pop out the "Input delay time" pop-up box,
enter the corresponding value and click OK to complete the modification, as
shown in Figure 3-1-31 below.
b. Relay mode
Click the relay type button, the "Relay model" pop-up box will pop out,
select the relay type relative to the actual one, as shown in Figure 3-1-32
below.
When using this function, you need to select normally open or normally
closed according to the type of relay connected during actual wiring.
c. Low volume reminder
Click the low-capacity reminder to pop up the pop-up box "Enter
low-capacity reminder", enter the corresponding capacity percentage and click
OK to complete the modification. When the KG-F mobile phone APP is
connected to the instrument's Bluetooth, of course, when the battery capacity
percentage is lower than the set value, it will be displayed in the A low-capacity
reminder is displayed in the status bar of the mobile phone, as shown in Figure
3-1-33 below.