Alarm Severity Classes
Alarms on ACX Series routers have two severity classes:
•
Major (steady red)—Indicates a critical situation on the router that has resulted from
one of the following conditions. A red alarm condition requires immediate action.
•
One or more hardware components have failed.
•
One or more hardware components have exceeded temperature thresholds.
•
An alarm condition configured on an interface has triggered a critical warning.
•
Minor (blinking red)—Indicates a noncritical condition on the router that, if left
unchecked, might cause an interruption in service or degradation in performance. A
minor alarm condition requires monitoring or maintenance.
A missing rescue configuration generates a minor system alarm.
Related
Documentation
• Verifying Active Alarms on page 124
• Monitoring System Log Messages on page 124
Copyright © 2017, Juniper Networks, Inc.126
ACX1000 and ACX1100 Universal Access Router Hardware Guide