mode (close | open);
trigger (ignore | red | yellow;
}
}
output{
port port-number {
input-relay input-relay;
mode (close | open);
temperature;
}
}
serial {
cts-absent (ignore | red | yellow);
dcd-absent (ignore | red | yellow);
dsr-absent (ignore | red | yellow);
loss-of-rx-clock (ignore | red | yellow);
loss-of-tx-clock (ignore | red | yellow);
tm-absent (ignore | red | yellow);
}
services {
hw-down (ignore | red | yellow);
linkdown (ignore | red | yellow);
pic-hold-reset (ignore | red | yellow);
pic-reset (ignore | red | yellow);
rx-errors (ignore | red | yellow);
sw-down (ignore | red | yellow);
tx-errors (ignore | red | yellow);
}
sonet {
(ais-l | ais-p | ber-sd | ber-sf | locd | lol | lop-p | los | pll | plm-p | rfi-l | rfl-p | uneq-p)
(ignore | red | yellow);
}
t3 {
(ais | exz | ferf | idle | lcv | lof | los | pll | ylw) (ignore | red | yellow);
}
}
cluster {
control-link-recovery;
control-ports {
fpc slot-number port port-number;
}
heartbeat-interval milliseconds;
heartbeat-threshold number;
redundancy-group {
... the redundancy-group subhierarchy appears at the end of the [edit chassis cluster]
hierarchy ...
}
reth-count number;
traceoptions {
file <filename > <files number> <match regular-expression> <size maximum-file-size>
<world-readable | no-world-readable>;
flag flag;
level severity;
no-remote-trace;
}
redundancy-group group-number {