The SFC management interface em0 is often displayed as fxp0 in several warning
messages. [PR/454074]
The VPN label does not get pushed on the label stack for Routing
Enginegenerated traffic with l3vpn-composite-next-hop activated. As a
workaround, configure per-packet load balancing to push the VPN/tunnel labels
correctly. [PR/472707]
On restarting with a large-scale configuration (16,000 logical interfaces per MPC),
the MPC-3D-16XGE-SFPP card may take up to 15 minutes to come up.
[PR/478548]
Swapping out eight FPC cards and replacing them with a different FPC type
causes the kernel to crash when the last FPC is powered on. [PR/502075]
The tty sessions to a router can cause a null pointer de-reference. [PR/502816]
The TTL for a GRE-encapsulated IPv6 packet malfunctions as the TTL on the wire
is one less than the CLI-configured tunnel TTL. [PR/506454]
In a setup with two VPN routing and forwarding tables (VRFs) of a provider edge
connected to different customer edges and auto-export configured, when a ping
is executed from a customer edge to a provider edge interface in the other VRF
, the Internet Control Message Protocol reply returns the source interface IP of
the provider edge that is connected directly instead of the interface IP of the
other VRF provider edge. [PR/510834]
Under certain conditions, traffic flow through an RLSQ bundle can be dropped
after it is removed and added back to a VPN routing and forwarding table (VRF).
[PR/518170]
Asp_ifl_update messages may be seen on routers running Junos OS Release 10.0
and above. Ignore these messages as they do not impact functionality.
[PR/532648]
Routing Policy and Firewall Filters
If a routing protocol running an MSDP receives an SA that is filtered via the MSDP
import policy, it will still create a forwarding entry if it subsequently receives a
(*,G) join for that group. [PR/63053]
The following features are not supported in a 12-16x10G DPC:
Known unicast and unknown unicast types in the input match condition
'Traffic-type' in a family bridge/VPLS
The following match conditions do not work:
learn-vlan-1p-priority
learn-vlan-1p-priority-except
learn-vlan-id
learn-vlan-id-except
user-vlan-1p-priority
user-vlan-1p-priority-except