Switch State Descripon
1 On INP1 is present.
O INP1 is not present.
2 On INP2 is present.
O INP2 is not present.
3 On Enabled for 30-A feed; 5,000 W for
single feed, 5,500 W for dual feeds.
O Enabled for 20-A feed; power supply
capacity is 3,000 W.
7. Plug the AC power cord into the power outlet.
8. If the power source outlet has a power switch, turn it on.
9. Turn on the power switch on the power supply.
10. If you’re using two power feeds, verify that the 1 and 2 LEDs on the power supply faceplates are steadily lit. These
LEDs correspond to INP1 and INP2.
Step 2: Up and Running
SUMMARY
Now that the MX10004 is powered on, let’s do some inial
conguraon to get the router up and running on the
network. It’s simple to provision and manage the MX10004
on your network.
IN THIS SECTION
Connect to the Router and Enter Conguraon
Mode  |  8
Connect to the Router and Enter Conguraon Mode
Before you begin conguring the router:
• Ensure that the Roung Control Board (RCB) has the Junos OS Release 22.3R1 or later operang system installed.