PROBLEMS
Cause Solution
• Insufficient or absent lubrication
• Verify oil and rings. Check oil pump efficiency
• Low tank oil level
• Fill tank with oil
• Excessive rotation speed
• Reduce rpm to the prescribed working speed
• Prolonged functioning at max vacuum rate
• Reduc
e vacuum rate
• Insufficient cooling
Check oil pump efficiency
.
Bleed the system with care
.
Check heat exchanger
efficiency
Vacuum and/or exhaust line of insufficient diameter
Check dimensioning
Cause Solution
• Br
oken vanes:
• Clean inner chambers, replace vanes
-
due to infiltrated solids
• Check the secondary shutoff and filters of the suction line
-
due to insufficient lubrication
• Check the oil pump
• Power transmission breakdown
• Check and replace the dam
aged parts
• Ice inside the pump (during the cold season)
• Remove ice and slowly start running it. Avoid suction of water
Cause Solution
• Four way changeover valve in idle position
• Move the lever to vacuum or pressure
mode end stroke
• Four way changeover valve not correctly registered
• Adjust the functioning play and lubricate
• Worn vanes
• Replace vanes
• The non
-
return valve leaks
• Clean or replace if necessary
• Worn seal rings
• Replace
• Tank gate valves o
r gaskets leak
• Replace damaged or worn parts
• Tank connection pipes leak or are obstructed
• Replace damaged pipes
• Obstructed primary shutoff or suction filter
• Remove and clean
• Encrusted exhaust port
• Remove and clean
• Vacuum line components
are too small dimensioned
• Verify dimensions for pump maximum performances
• Obstructed rubber couplings
• Replace
Cause Solution
• Insufficient or absent lubrication
• Check and adjust the lubricating pump
Recycling materials allow reducing the environmental impact and
respecting the environment.
Do not dispose of in the environment. Dispose of
in compliance with the standards in force.
Before scrapping the machine, the following materials need to be
separated and suitably disposed of:
Material Cast Iron Steel Alluminum Copper Bronze Rubber Vane Oil Gasket
LC 300 88,0 % 9,0 % 0,6 % 0,2 % 0,1 % 0,4 % 0,6 % 0,5 % 0,4 %
LC 420 89,0 % 8,0 % 0,6 % 0,2 % - 0,3 % 0,8 % 0,5 % 0,4 %
LC 580 88,0 % 9,0 % 0,5 % 0,2 % - 0,3 % 0,9 % 0,4 % 0,4 %
Unusual oil consumption
Reduced performances
The vacuum pump does
not rotate
8.
Scrapping
The vacuum pump overheats
7
.
Malfunctions: troubleshooting

Other manuals for jurop LC 580

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jurop LC 580 and is the answer not in the manual?

jurop LC 580 Specifications

General IconGeneral
Brandjurop
ModelLC 580
CategoryWater Pump
LanguageEnglish

Related product manuals