and 4
 
00 Fence Triggers when Zone 1 is armed and return voltage is below set threshold voltage
01 Fence or O Triggers when Zone 1 is o or return voltage is below the threshold voltage
02 Armed Zone 1 is armed
06 Fence Bi-Polar Triggers when energiser is armed and the fence return voltage on either Bi-Polar return line
has fallen below the threshold voltage
07 General Triggers on AC Fail, Tamper, Low Battery/Bad Battery, Gate Alarm or Internal error. Latched
(internal errors only)
08 Siren Triggers on Fence alarm , Gate or tamper. Will time out after the Siren Time Out time.
Latched
09 Strobe Triggers on Fence alarm, Gate or Tamper. Only turns o on Energiser disarm. Latched
10 AC Fail Triggers on AC Fail
11 Low/Bad Battery Triggers on low or bad battery
12 Tamper Triggers when the case has been opened and j3 has been tted (Z14R only)
14 Gate Triggers on Gate