EasyManua.ls Logo

JVC KD-V6B - Indicator and Level Adjustment; Peak Indicator vs. FL Meters; Setting Optimum Recording Level

JVC KD-V6B
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Relation
between
DIGITAL
PEAK
indicator
and
FL
PEAK
meters
Although
the
levels
of
these
are
the
same
because
they
are
controlled
by
a
single
microcomputer,
the
DIGITAL
PEAK
indicator
is
more
precise
between
+3
dB
and
+9dB
because
it
can
show
values
which
cannot
be
shown
by
the
FL
PEAK
METER
(+4
dB,
+6
dB,
etc.).
Setting
the
optimum
recording
level
for
different
types
of
tape
Adjust
the
recording
level
while
observing
the
DIGITAL
PEAK
indicator
and
FL
meter.
For
example:
With
Metal
tape
Bei
Metallband
Bande
métal
015
107
5
3
2
Because
of
metal
tape’s
higher
saturation
level,
it
is
OK
that
the
DIGITAL
PEAK
indicator
is
“+9
dB”.
Auf
Grund
des
héheren
Sattigungsgrades
des
Metailbandes
Le
|
aeet|
10123
5
7
9+
BIOSIS
Rooy
Pert
METAL
Zusammenhang
zwischen
DIGITAL
PEAK-Anzeige
und
FL
PEAK
METER
Obwohl
die
Pegel
identisch
sind,
da
sie
Uber
denselben
Mikrocomputer
geregelt
werden,
ist
die
DIGITAL
PEAK-
Anzeige
im
Bereich
zwischen
+3
dB
und
+9
dB
praziser,
da
der
FL
PEAK
METER
nicht
alle
Werte
anzeigen
kann
(z.B.
+4
dB,
+6
dB
etc.).
Einstellung
des
optimalen
Aufnahmepegels
fiir
verschiedene
Bandarten
Den
Aufnahmepegel
unter
Beobachtung
der
DIGITAL
PEAK
und
FL-Anzeige
einstellen.
Beispiel:
Relation
entre
l’indicateur
DIGITAL
PEAK
et
les
compteurs
FL
PEAK
Bien
que
les
niveaux
de
ceux-ci
soient
les
mémes
parce
qu’ils
sont
contrélés
par
un
seul
microordinateur,
|’indica-
teur
DIGITAL
PEAK
est
plus
précis
entre
+3
dB
et
+9
dB
parce
qu’il
peut
indiquer
des
valeurs
qui
ne
sont
pas
indi-
quées
par
FL
PEAK
METER
(+4
dB,
+6
GB,
etc.).
Réglage
du
niveau
d’enregistrement
optimal
pour
différents
types
de
bande
Ajuster
le
niveau
d’enregistrement
tout
en
observant
I’indi-
cateur
DIGITAL
PEAK
et
le
compteur
FL.
Par
exemple:
With
Normal
or
Chrome
tape
Bei
Normalband
Bande
ordinaire
ou
Chrome
2001
107
5 3 2
DIF
RERE
RR
ESS.
.
10123
5
7
9+
=
GIS
SSS
S
SSE
oy
it
is
OK
that
the
DIGITAL
PEAK
indicator
is
“+5
dB”,
Die
DIGITAL
PEAK-Anzeige
von
+5
dB
ist
zulassig.
ist
die
DIGITAL
PEAK-Anzeige
von
+9
dB
zulassig.
Du
fait
que
les
bandes
métal
ont
un
niveau
de
saturation
Plus
élevé,
il
est
normal
que
l'indicateur
DIGITAL
PEAK
montre
“+9
dB”.
e
It
is
best
to
adjust
the
recording
level
near
the
tape’s
saturation
level.
The
best
level
varies
depending
on
the
type
of
music
and
type
of
tape
so
it
is
better
to
make
test
recordings,
using
FM
music,
records,
etc.
e
Am
besten
ist
die
Einstellung
des
Aufnahmepegels
nahe
des
Sattigungsgrades
des
Bandes.
Jedoch
unterschieden
sich
diese
Einstellungen
je
nach
Musikstil,
Bandsorte,
und
es
sollten
deshalb
Probeaufnahmen
durchgefihrt
werden
(UKW-Musikaufnahmen,
Schallplatten
etc.).
Hest
normal
que
lindicateur
DIGITAL
PEAK
montre
“+5
dB”.
e
//
est
préférable
de
régler
le
niveau
d’enregistrement
prés
du
niveau
de
saturation
de
la
bande.
Le
meilleur
niveau
possible
dépend
de
la
nature
de
la
musique
et
de
la
bande,
de
sorte
qu’il
est
préférable
de
faire
des
essais
d‘enregistrement,
4
partir
de
musique
en
FM
ou
de
dis-
ques
etc.
24

Related product manuals