Hardware Control Setup
The Kommander-KA02 power amplifier provides a General
Purpose Input connector designed to connect up to four
external normally open (NO) switches* to be set as further
remote user customizable controls.
In order to bind the remote control to a Kommander-KA02
operating functionality (actions) follow these step:
1. Connect the external NO switch to the ground (GND) terminal and to
one of the four available terminals of the flying plug;
2. Plug the flying plug to the Hardware Control port on theKommander-
KA02 back panel;
3. Open the Azimut Control interface, click on the Main Menu icon and
select Advanced;
4. Scroll down to theHardware Control section;
5. Find the control with the number corresponding to the hardware control
terminal where you plugged the remote switch and set the proper
action;
6. Enable the remote control;
7. Click on Save Setup to make the settings effective.
Actions
mute/unmute
set volume
(max: +12, min: -90)
Increase volume
Decrease volume
play/pause
play/pause Spotify
bluetooth pairing
*external normally open (NO) switches
are not provided in the amplifier
package.