Cleaning on
request ( 1 )
Before removing the drip
trays, make sure that the
spout is in the uppermost
position.
Danger to health! Care-
fully read the user instruc-
tions for the cleansing agent
and follow the safety instruc-
tions.
If the cleaning process is
interrupted, the appliance
returns to the cleaning
mode automatically when
switched on again.
For health reasons it is rec-
ommended to maintain the
factory setting of the auto-
matic cleaning request.
The filter must be removed
prior to cleaning.
Only use cleaning agents that are suitable
for the appliance. For further information,
please visit our website at:
www.k-fee-system.com
4
5
7
°C
8
6
3
2
Open lever and close again.
Remove drip trays with spent
capsule container.
Remove and empty water
tank.
Fill water tank with cleaning
agent (100 ml) and 400 ml
water.
°C
°C
Empty container and then re-
insert into the appliance.
0.4 L
Insert water tank. Place a
container under spout.
After 100 beverage preparations, the appliance automatically
prompts for a cleaning cycle (factory setting).
°C
°C
Press rinsing button for at
least 3 sec.
min.
0.6 l