Questions and Answers

  • W
    walkerkennethAug 13, 2025
    How to fix K2 Pumps Water Pump that runs but does not discharge water?
    • J
      John WardAug 14, 2025
      If your K2 Pumps Water Pump runs but doesn't discharge water, first, ensure the anti-airlock hole is clear. Then, lay the pump on its side and stand it upright in the water to release trapped air from the impeller area. Also, verify the discharge hose or pipe isn't blocked or too narrow, and doesn't exceed the pump's maximum head capability. Inspect the impeller for damage or clogs, and ensure any check valve is correctly installed to allow water flow.
  • C
    Cindy FlowersAug 17, 2025
    What to do if K2 Pumps Water Pump motor hums but isn't pumping?
    • R
      riveralaurenAug 17, 2025
      If your K2 Pumps Water Pump motor hums but the pump isn't running, check for debris jamming the impeller area and remove any obstructions to ensure free rotation. Inspect the cooling shroud and vents for foreign objects or shifting, and correct as needed. If these steps don't resolve the issue, the motor may have failed, requiring pump replacement.
  • L
    luiswoodAug 21, 2025
    Why K2 Pumps UTA02502K Water Pump does not run at all?
    • L
      laura80Aug 21, 2025
      If your K2 Pumps Water Pump isn't running or making noise, first, check the outlet for power and ensure the plug is properly connected. Next, make sure the water sensing probes are submerged in at least 1-1/4 inches of water and are free from debris. If the pump has overheated, allow it to cool down. Avoid operating the pump when liquid temperatures are below 30°F or above 77°F. If these steps don't work, the internal connection or motor may have failed, requiring pump replacement.
  • P
    pauladkinsAug 25, 2025
    What to do if K2 Pumps Water Pump moves less water than it should?
    • K
      Kevin DavisAug 26, 2025
      If your K2 Pumps Water Pump moves water, but the quantity is less than expected, use a shorter, wider discharge hose, ensuring it's straight and free of kinks. Remove any debris blocking the intake area to ensure it is clear. Keep the discharge elevation within the pump's capacity. Inspect the impeller and other internal parts for wear or damage and repair as needed.
  • L
    lwilliamsAug 28, 2025
    Why is there oil around my K2 Pumps UTA02502K?
    • T
      Tanya PetersAug 28, 2025
      The oil around your K2 Pumps Water Pump and in the water indicates that a standard submersible utility pump is being used in a pond or waterfall, causing it to overheat and expel its dielectric oil. To resolve this, use a pump specifically designed for waterfall or pond use. Also, running the pump for shorter periods with breaks for cool-down can prevent overheating. If the pump is used in a fish pond, fish waste may have damaged the shaft seal. In this case, use only waterfall-type pumps.
  • E
    Erica ProctorSep 1, 2025
    Why does the impeller wear out so quickly on my K2 Pumps Water Pump?
    • C
      carly81Sep 1, 2025
      The impeller of your K2 Pumps Water Pump may be wearing out quickly due to sand, dirt, or grit in the water, as these pumps are designed for clear water. Pumping liquids other than water can also cause accelerated wear because these liquids lack the necessary lubricating qualities. Ensure that you only pump clear fresh water to prolong the life of the impeller.
  • M
    Michael WhiteSep 5, 2025
    What causes a K2 Pumps Water Pump impeller to break?
    • T
      tyler51Sep 5, 2025
      The impeller of your K2 Pumps Water Pump may be broken because the pump has picked up debris that caused the damage. To prevent this, take care to keep debris from being drawn into the pump.
  • F
    franciscojacksonSep 9, 2025
    Why is my electronic K2 Pumps UTA02502K Water Pump not working correctly?
    • R
      Ronald BellSep 9, 2025
      If your electronic K2 Pumps Water Pump isn't working as described, ensure the discharge hose isn't too restrictive (narrow, long, or high). Plug the pump directly into an outlet, avoiding extension cords, timers, or ground fault interrupter circuits. If the pump runs continuously after the water is gone, the internal sensing circuitry may have failed. In this case, clean the water sensing probes.

Summary

Performance Specifications

Safety Instructions

Pre-Installation

Application

Describes the pump's intended uses and limitations for water removal.

Tools Required

Lists the necessary tools for installing the submersible utility pump.

Materials Required

Lists materials needed for installation but not included with the pump.

Specifications

Details technical specifications such as power supply and liquid temperature range.

Installation

Operation

Airlock

Care and Cleaning

Troubleshooting

Warranty

Limited Warranty

Outlines what the warranty covers, does not cover, and other important terms.

K2 Pumps UTA02502K Specifications

General IconGeneral
ModelUTA02502K
CategoryWater Pump
Horsepower1/4 HP
Voltage115V
Frequency60 Hz
Maximum Flow Rate1800 GPH
Max Flow Rate1800 GPH
Maximum Head25 ft
Max Head25 ft
Cord Length6 ft
ConstructionThermoplastic
MaterialThermoplastic
Discharge Size1 inch
Inlet Size1 inch
Outlet Size1 inch

Related product manuals