TRACKSO INSTALLATION GUIDE FOR KACO INVERTERS
Brand: KACO
Type: Solar On Grid String Inverter
Models: KACO Blueplanet Series with Modbus TCP Communication (Sunspec)
CONNECTION DIAGRAM
Locate communication terminals (Ethernet Port) as shown in the picture below.
Figure K1: Kaco String Inverter Communication Circuit Board
Connection steps
• Locate the communication card as shown in Figure S1
• Guide the network cable (LAN) through the cable glands and Connect the Ethernet cable to the inverter.
• Configure the Ethernet interface in the configuration menu.
• Connect the Ethernet cable to the Data Logger
• Configure the Ethernet settings in the settings menu
• Provide 12V DC external supply to Data Logger
•
Provide Internet to Data Logger
DEFAULT CONFIGURATION IN DATA LOGGER
Inv-1 -> ID-1, IP-192.168.0.10, Port-502
Inv-2 -> ID-2, IP-192.168.0.11, Port-502
Inv-3 -> ID-3, IP-192.168.0.12, Port-502
continuous to the max no. inverters allowed.
CONFIGURATION AT THE INVERTER END