23
AC current
Range Resolution Accuracy
600A 0.1A
±(1.5% reading+3)
6000
A 1
A
60mA 0.01mA
600mA 0.1mA
10A 0.01A
Overload protection
A/mA
F600mA/250V fuse
10A
F10A/250V fuse
Maximum input current
mA: 600mA
A: 10A
Frequency Response
10Hz ~ 1kHz
True-RMS
When measuring large current, continuous measurement
should be no longer than 15 seconds
Resistance
Range Resolution Accuracy
600Ω 0.1Ω
±(1.0% reading+3)
6kΩ 0.001kΩ
60kΩ 0.01kΩ
600kΩ 0.1kΩ
6MΩ 0.001MΩ
±(1.5% reading+3)
60MΩ 0.01MΩ
Overload protection
250V