Loading...
Page 17
Temperature display
Tf 49.2
o
C
Flue temperature (
o
C)
Ti 14.6
o
C
Inlet temperature (
o
C) Normally set by
the flue probe during the fresh air purge.
Press the SEND/PRINT button for 1 second to print the full combustion
test.
Press and hold the SEND/PRINT button for approximately 2 seconds to
store the combustion test in the memory.
Press the BACKLIGHT key for one second to “freeze” the readings
before printing.
Fuel display
SET FUEL
Set the fuel source.
NATU GAS
Fuel source currently selected
Use the / scroll to the required fuel source.
Press the button to select the fuel source. DONE will be briefly
displayed on the bottom line of the display.
Date/Time display
14 : 47 : 15
Current time. Can be reset via “Menu”
.
23 / 01 / 14
Current date. Can be reset via “Menu”.