KANE455 manual Page 14
Press / to print a full combustion test, (or send to PC via optional
Bluetooth).
Hold
/ for 2+ seconds to log a full combustion report.
AUX display
P 0.00
The AUX (auxillary) display can be
customised via MENU / SCREEN / AUX.
R 0.0008
The parameters displayed on lines 1, 2, 3 and
4 can be set by the user.
COp 52
They remain the AUX parameters until
changed by the user.
CO2% 6.3
Press / to print a full combustion test, (or send to PC via optional
Bluetooth).
Hold
/ for 2+ seconds to log a full combustion report.
Viewing / printing a logged combustion test
Select MENU / REPORT / COMB’N / VIEW
Use
, and to select the log number to be viewed.
Use
and to scroll through the individual readings on lines 2 & 3.
Hold
or for 2+ seconds to scroll to the next / previous log number.
Press
/ to print the test, (or send to PC via optional Bluetooth).