KANE455 manual Page 24
6. USING THE KANE455 AS A THERMOMETER OR
PRESSURE METER
With the KANE455 switched off, press and hold down the / button and
then press and release / . Release / after MANO_MOD
is displayed on top line.
The KANE455 will now operate as a fixed display thermometer/pressure meter with
the pump off and inhibited. The readings can be printed but not stored.
The display will show:
P 0.00
Real time pressure reading.
T1 21.3
Use the T1 connection for the flow
temperature sensor.
T2 21.3
Use the T2 connection for the return
temperature sensor.
T 0.0
Real time temperature difference.
The standard printout for this mode is as follows:
K455 1.0
YOUR COMPANY NAME &
PHONE NUMBER HERE
DATE 15/05/07
TIME 13:00:47
…………….…………………………
T1
o
C 21.3
T2
o
C 21.3
T
o
C 0.0
PRS mbar 0.00
………………………………………
Ref.
………………………………………
Exit ‘Mano-Mod’ by switching the KANE455 off.
The ‘Menu’ and ‘Tighness’ positions still operate normally in ‘Mano-Mod’