T600 Tag Tester
DOC#: UM 360420-835 REVISION F Page 29 of 55
© Kapsch TrafficCom Canada Inc. 2022
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose intended
and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360420-835 REV F, T600 OPERATOR AND MAINTENANCE MANUAL.DOCX 03/28/2022 3:02
Kapsch TrafficCom
Command
How is this command executed?
Who can execute this
command?
What does this command do?
What is the purpose of this
command?
Accept
After a calibration margin test returns
Read and Write dB values,
click on Accept.
Kapsch service personnel
Accepts the calibration margin
test results.
To use the Read and Write
calibration margin test results
as the criteria for OBU tests of
this type.
New Log File
Click on New Log File.
anyone
Opens the Open file window.
To specify to which text file
new log records are added.
Log Only Failed
Tests
Select the Log Only Failed Tests check
box.
anyone
Sets the T600 to only log tag
failures to the log file.
Enabled: to log only failed tag
tests to the log file.
Disabled: to log all tag tests to
the log file.
Comm. Port
(T600)
From the Communication tab in the
Configuration Dialog window,
select the computer COM port that is
connected to the T600 HOST port from
the T600 Comm. Port drop-down box,
then,
Click OK.
anyone
Establishes which computer
COM port is connected to the
T600 HOST port.
To establish which computer
COM port is connected to the
HOST port.