Operation and Service KBL 6800/6900
6. Technical data
6.1 Data which all apparatuses have in common
Ambient conditions
Condensate
Dimensions
Installation site In dry rooms with suf!cient air supply and ventilation
Relative humidity ≤70%
Ambient temperature ≤86°F (30°C)
ATTENTION! The unit must not be operated if the coin/timer system or
the internal control system of the maximum tanning time
is defective or if a filter is broken or missing.
Mains voltage
3-phase: 3x 220 V / ~ / 60 Hz
2-phase: 2x 220 V / ~ / 60 Hz
Wire cross section
3-phase: 4x AWG6
2-phase: 3x AWG8
Outlet At the left-hand rear side of the unit
Disposal Connection to sewage system or tank (capacity ≥5l)
Quantity Depending on local conditions and air humidity
Note For the purpose of pumping the water off, the power
supply must not be disconnected after the tanning
session
Length x width x height ~92.91” x ~53.15” x ~55.12” when closed
~92.91” x ~53.15” x ~70.87” when opened
Central exhaust air duct
Diameter
Height (top edge)
~11.81”
~62.99”
Exhaust air hose Ø ~11.81”
Weight (with air-
conditioning unit)
~1477.1 lbs