HOW TO INSTALL
Push the main body upward into the ceiling board
and wooden frame by closely leaning against the
adapter, clip the clipping position of the main body
into the locating slot of the adapter (otherwise,
may have air leakage), and fix the main body with
six 4 x 30 self- tapping screws.
6
Notice
Please be careful not to pinch the cord, when push
upward the main body.
(否 風)使
6 4x30
Locating slot of the adapter
Clipping position
of the main body
Self-tapping
screws
4 x 30 (6 pcs)
4x30(6 )
10
Loosen the screws of the cord clip.
Loosen the screws of the pillar terminal , insert the
power cord(not supplied)connected to the fixed
wiring which in the house into the pillar terminal ,
tighten the screw.
Fix the cord cover by the screws which
removed by step .
驟 拆
( )
Fix the power cord with the cord clip.
(The cord clip must pin the insulation
sheath of power cord.)
CAUTION
When covering the terminal cover, be sure not to suppress
the earth wire, otherwise it may damage the earth wire.
Screws
Cord clip
Terminal
Earth
wire
Screws
Cord clip
Terminal cover