Do not install onto slanting ceilingboard.
Prevent the water condensed in the
duct pipe flow back into the body.
Pleasemakesuretheproductis installed
horizontallyandthedeviationangle
withintherangeasbelowfigure.
5
Do not install the product in the places
where the organic solvent is used.
Do not install the product in steam
sauna bathroom.
Do not install the product where it is
exposed to oil mist.
Do not install the product in the
places where the sprayer is used.
使
使
Please set ventilation holes.
Ambient temperature
above 40 °C.
Within
50 cm
50 cm
Do not install the product in places
with high temperature.
40 °C
INSTALLATION REQUIREMENTS
Steam
±2°
When the ceiling board is unable to
dismantle, please set a square inspection
hole of at least 45 cm (The inspection
hole should not be directly under the
duct pipe).
45 cm(
)。
便
Convenience for
installation and
maintenance.
Wave pipe
Adapter
Do not form the duct as shown below:
Do not install this product in a public bath room.
Do not install this product in a wardrobe.
The pipe for hanging clothes should be installed at the position of 250 mm
apart from the product, please see P.24 for details.
250 mm24
Please install on a flat ceiling board.
(450 mm)
(150 mm)
(450 mm)
square
inspection
hole