CP-Parameter
Value Function
63 Absolut value ANOUT1 > switching level
1)
64 Absolut value ANOUT2 > switching level
1)
65 ANOUT1 > switching level
1)
66 ANOUT2 > switching level
1)
70 Driver voltage activ (safety relay)
73 Absolut active power > switching level
1)
74 Active power > switching level
1)
Unlisted values are only for application mode
1)
Switching level of CP.33 = 100; switching level of CP.34 = 4
CP.35 Limit switch / stopping mode
This parameter determines the reaction of the drive to terminal X2A.14 (F) and/or X2A.15
(R), which are programmed as limit switches. The reaction of the drive is shown in the
table below.
CP.35 Display Response Restart
0 E.PRx Immediate disabling of modulation
Remove fault,
reset
1 A.PRx
Quick stopping / disabling of modulation after
reaching speed 0
2 A.PRx Quick stop / holding torque at speed 0
3 A.PRx Immediate disabling of modulation
Autoreset, if no fault
is present
4 A.PRx
Quick stopping / disabling of modulation after
reaching speed 0
5 A.PRx Quick stop / holding torque at speed 0
6 None No effect to the drive, fault is ignored ! Inapplicable
CP.36 External Fault / stopping mode
With the external error monitoring external units can take direct inuence on the drive.
This parameter determines the response of the drive to a signal at terminal X2A.12 (I3)
according to following table.
CP.36 Display Response Restart
0 E.PRx Immediate disabling of modulation
Remove fault,
reset
1 A.PRx
Quick stopping / disabling of modulation after
reaching speed 0
2 A.PRx Quick stop / holding torque at speed 0
3 A.PRx Immediate disabling of modulation
Autoreset, if no fault
is present
4 A.PRx
Quick stopping / disabling of modulation after
reaching speed 0
5 A.PRx Quick stop / holding torque at speed 0
6 None No effect to the drive, fault is ignored ! Inapplicable

Table of Contents

Other manuals for KEB ACOMBIVERT F5 X3A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB ACOMBIVERT F5 X3A and is the answer not in the manual?

KEB ACOMBIVERT F5 X3A Specifications

General IconGeneral
BrandKEB
ModelACOMBIVERT F5 X3A
CategoryDC Drives
LanguageEnglish

Related product manuals