8. Parameter Description
Terminal X2 (upper terminal)
With the X.2 input state it is easy to control whether the input signals
reached the inverter control. Every input (output) has a specific
valency. If some inputs are set, the sum of the valency is shown.
Value Table:
X2 Input State
Display of the software version.
Software Version
Software Date
Display of the software date.
Display Valency Function Input
Combivis Terminal
ST 1 control release X2.1
RST 2 reset X2.2
F 4 direction of travel forward X2.3
R 8 direction of travel reverse X2.4
I1 16 control mode X2.5
I2 32 drive active X2.6
I3 64 door drive setpoint input X2.7
Example: Input control release (X2.1), direction and travel up (X2.3)
and external error (X2.5) are triggered with 24V .
Display value: 1+4 = 5
X2 Output State
Terminal X2 (upper terminal)
With the X.2 output state it is easy to control, whether the outputs
were set by the inverter control. Every digital output has a specific
valency. If some outputs are set at the same time, the sum of the
valency is shown.
Value table:
Display Valency Function Input
Combivis Terminal
O1 1 digital output signal: X2.8
braking control
O2 2 digital output signal: X2.9
main contactor control inverted
O3 4 relay control cabinet fan X2.20/X2.21