8. Parameter Description
Terminal strip X3 (lower terminal)
see parameter LF.82 for functional description.
Value table:
X3 Input State
X3 Output State
Terminal X3 (lower terminal)
See parameter LF.83 for functional description.
Value table:
Display Value: 0 1 23456 7
Speed: V=0 V
B
V
E
V
N
V
I
V
1
V
2
V=0
Display of the actual inverter utilization in %.
Actual Set Value
Actual Inverter
Utilization
Display Valency Function Input
Combivis Terminal
O5 1 Signal: ready overspeed X3.13
O7 4 Relay contact: braking control X3.15/X3.16
O8 8 Signal: operating frequency warning X3.14
O9 16 Signal: delay control X3.17
O10 32 Relay contact: crawl speed X3.18/X3.19
O12 128 Relay contact: main contactor control X3.20/X3.21
O14 1024 Signal: DC-monitoring X3.22
O15 4096 Signal: motor temperature warning X3.23
Display Valency Function Input
Combivis Terminal
I5 1 Input signal: contactor control X3.1
I6 2 Set value correction speed: V
B
X3.2
I7 4 Set value crawl speed: V
E
X3.3
I8 8 Set value rated speed: V
N
X3.4
I9 16 Set value inspection speed: V
I
X3.5
I10 32 Set value 1st intermediate speed: V
1
X3.6
I11 64 Set value 2nd intermediate speed: V
2
X3.7
The value shows the actual set speed in rpm, calculated from the
system data.
Actual Set Speed