GB 44
GB
The value shows the real speed in rpm, led from the impulses of
the incremental encoder .
Actual Speed
Actual Lft Speed
ASM - Rated Motor Torque
Display of the speed in m/s; only when the encoder is connected.
8. Parameter Description
Display Significance
StOP no setpoint selection
S.Co setpoint selection without contactor control
S.IO setpoint selection without control release
S.nC no current flows on the output side, check the wiring
between motor and inverter
run starting procedure is completed
Display Value Significance
bbl 76 base-block-time runs out, power modules are blocked
for 3s (always when control release is cleared)
Facc 64 forward acceleration
Fcon 66 forward constant running
FdEc 65 forward deceleration
nOP 0 no Operation, terminal X2.1 is not set
LS 70 low speed, control release is switched but no
direction of rotation is adjusted, modulation disabled
rAcc 67 reverse acceleration
r Con 69 reverse constant running
rdEc 68 reverse deceleration
The parameter shows the fault indications that occur during the
starting process and continuous operation.
Using the rating plate data the inverter determines the motor rated
torque in the rated point. Unit Nm.
Unit: Newton meter
Factory setting: 26,5 Nm
See parameter LF.99 for more information about other fault indications.
Error State
Display of the positioning drive in cm, after the drive has finnished.
Positioning Drive
a) Running Messages
Inverter State

Other manuals for KEB COMBIVERT F4-F