GA1060 Field bus master module Configuration
Project Engineering Manual, version: 1.1 / article no.: 1000296 9
© KEBA 2006
3 Configuration
Only a name has to be assigned for the configuration of the FM 299/A. In
addition, the GA1060 bus must be configured, also with its name and the
cycle time.
The FM 299/A can be configured at the CPU module in two different ways:
Via Kemro.manager
through the creation of cfg-files with a text editor
Two FM 299/A modules can be operated on one CPU.
Configuration with the KEMRO.Manager
The Kemro.managers can be used to configure all modules of a systems as
well as the Sanyo Denki converters of the QSE series.
At selection of the FM 299/A one column is automatically created for the
bus connection, which is then used to connect the drives.
Once all modules have been specified in the system and after all
parameters have been adjusted the Kemro.manager creates the necessary
cfg-files.