Electric scheme Mirage 3-phase: Duette high power/Triplette
Figure T 2. Schematics of the 230VAC circuit in the Mirage Duette high power (5200W) and Mirage
Triplette (6400W). Wires on grey connector block are marked "I". "II" or "III" according to individual
circuit. Compare to Figure T 5 and Figure T 6. NB: the control power from ST25 to SSR's is 12VDC.
2
2
1
2
1
1
1
Gr mains ground
N mains neutral
P1 mains phase 1
P2 mains phase 2
P3 mains phase 3
16A fuse
CW cold water valve
HW
hot water valve
Fill fill valve
GrL
group valve left
GrM group valve middle
GrR group valve right
StL steam valve left
StR steam valve right
MS mains switch CB mains connector block
OHSS overheat safety switch GC Gicar 12-pole connector
HS heating spiral SSR solid state relay
IL indicator light ST25 temperature controller
StR
N
P1
P2
P3
8
9
10
11
12
GC
4
5
OHSS
GrR
GrR/GrM
StL
6
GrL
7
1
1
HW
2
CB
Fill
3
CW
4
MS
3
pump
2
Gr
N
P1
P2
P3
IL
HS
HS
HS
IL
IL
ST25
SSR
SSR
SSR
16A
16A