KellyFullBridgePermanentMagnetMotorDcControllerUser’sManual V1.4
14
operation.
3,3 ¤¤¤ ¤¤¤
Hallthrottleis
openor
short-circuit
Whenthethrottleisrepaired,arestartwillclearthe
fault.
3,4 ¤¤¤ ¤¤¤¤
Non-zerothrottle
ondirection
change
Controllerwon’tallowadirectionchangeunlessthe
throttleorspeedisatzero.Faultclearswhen
throttleisreleased.
4,1 ¤¤¤¤ ¤
RegenorStart-up
over-voltage
Motordriveisdisabledifanover-voltageis
detectedatstart-uporduringregen.Thevoltage
thresholddetectionlevelissetduringconfiguration.
Themaxthresholdisabout1.25timesofcontroller
ratedvoltage.I.e.youmaysetthresholdlowerthan
60Vfor48Vcontroller.
4,3 ¤¤¤¤ ¤¤¤
Motor
over-temperature
Motortemperaturehasexceededtheconfigured
maximum.Thecontrollerwillshutdownuntilthe
motortemperaturecoolsdown.
CustomersmayreaderrorcodesormessageinPCsoftwareorAndroidApp.