• Loosen the hexagon socket head screw (1) until the bearing (2) is released
and pressed against the outer edge of potentiometer (3) (look in the gap
between the regulator frame and the potentiometer).
Restoring the RMT 10 into its normal state, where potentiometer positions
corresponding to Selecto channels are not felt:
• Turn the potentiometer (3) a little so that the bearing (2) is forced out of the
groove on the potentiometer edge.
• Tighten the screw (1).
10
PMT © Kemppi Oy / 1130