5. TROUBLESHOOTING
NOTE! The problems listed and the possible causes are not denitive, but serve to suggest some
standard and typical situations that may present during normal environmental use when using
the MIG/MAG process with FastMig X 450.
Problem Check the following
Machine won’t work
• Check mains plug is connected correctly
• Check mains power distribution is switched on
• Check the mains fuse and or circuit breaker
• Check power source 0/I switch is ON
• Check interconnection cable set and connectors between the power source and
wire feed unit are correctly fastened. See the manual schematic
• Check earth return lead is connected
• Check control panels are switched on.
Dirty, poor quality weld
• Check shielding gas supply
• Check and set gas ow rate
• Check gas type for application
• Check gun/electrode polarity
• Check correct welding program selected
• Check correct channel number selected on wire feeder control panel
• Check power supply – Phase down?
Variable welding performance
• Check wire feed mechanism is correctly adjusted
• Check correct drive rolls are tted
• Check wire spool overrun tension is correctly adjusted
• Check gun liner is not blocked, replace if necessary
• Check correct gun liner is tted for the ller wire size and type
• Check contact tip for size, type and wear
• Check gun is not over heating in application
• Check cable connections and earth return clamp
• Check welding parameter settings.
Filler wire won’t feed
• Check that pressure arms are closed and adjusted in wire feed mechanism
• Check welding gun switch function
• Check Euro gun collar is correctly fastened
• Check gun liner is not blocked
• Check contact tip, size, type, wear
• Check and try alternative gun
High spatter volume
• Check welding parameter values
• Check inductance/Dynamics values
• Check cable compensation value if long cables are tted
• Check gas type and ow
• Check welding polarity – cable connections
• Check ller material selection
• Check correct welding program selected
• Check correct channel number selection
• Check ller wire delivery system
• Check power supply – 3-phase present?
Err1 Power source is not calibrated or calibration data cannot be read
• Restart power source
• if the problem continues after multiple startups contact Kemppi service
representative
Err 3 Overvoltage in the mains supply
• Check the mains voltage
21
© Kemppi Oy / 1312

Other manuals for Kemppi FastMig X 450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi FastMig X 450 and is the answer not in the manual?

Kemppi FastMig X 450 Specifications

General IconGeneral
BrandKemppi
ModelFastMig X 450
CategoryWelding System
LanguageEnglish

Related product manuals