2.3 Distribution network
All regular electrical devices without special circuits generate harmonic currents into
distribution network. High rates of harmonic current may cause losses and disturbance to
some equipment.
Kempact 181A, 251R, 251A:
Equipment complying with IEC 61000-3-12
Kempact 253R, 253A:
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc
is greater than or equal to 2.7 MVA at the interface point between the users supply and
the public supply network. It is the responsibility of the installer or user of the equipment
to ensure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power Ssc greater than or equal
to 2.7 MVA.
Kempact 323R, 323A:
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc
is greater than or equal to 2.1 MVA at the interface point between the users supply and
the public supply network. It is the responsibility of the installer or user of the equipment
to ensure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power Ssc greater than or equal
to 2.1 MVA.
Kempact 251 MVU:
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc
is greater than or equal to 1.1 MVA at the interface point between the users supply and
the public supply network. It is the responsibility of the installer or user of the equipment
to ensure, by consultation with the distribution network operator if necessary, that the
equipment is connected only to a supply with a short-circuit power Ssc greater than or equal
to 1.1 MVA.