WELDING AND EARTH CABLES3.6
Recommended copper cables with cross-sectional area are as follows:
FastMig KMS 400 AS 70 ... 90 mm²
In enclosed table are shown typical load capacities of rubber insulated copper cables, when
ambient temperature is 25 ºC and lead temperature is 85 ºC.
Cable Duty cycle ED Voltage loss / 10 m
100 % 60 % 30 %
50 mm² 285 A 370 A 520 A 0,35 V / 100 A
70 mm² 355 A 460 A 650 A 0,25 V / 100 A
95 mm² 430 A 560 A 790 A 0,18 V / 100 A
Do not overload welding cables due to voltage losses and heating.
Fasten the earth clamp of the return current cable carefully, preferably direct onto the piece to
be welded. The contact surface of the earth clamp should always be as large as possible.
Clean the fastening surface from paint and rust.
KMS AS PANEL3.7
KMS AS
W004538
A
CC CV
UI
V
CC
MSF
CV
CC
SETUP
ARC FORCE
DYNAMICS
KMS AS
W004538
A
CC CV
UI
V
CC
MSF
CV
CC
SETUP
ARC FORCE
DYNAMICS
ON/OFF –button
KMS AS
W004538
A
CC CV
UI
V
CC
MSF
CV
CC
SETUP
ARC FORCE
DYNAMICS
Dynamics can be adjusted both in MIG and MMA-welding
KMS AS
W004538
A
CC CV
UI
V
CC
MSF
CV
CC
SETUP
ARC FORCE
DYNAMICS
CC= Constant current mode. Selection by longtime press. Selected when operated with Arcfeed with
CC-mode or MMA welding
MSF mode = Use with MSF or MXF feeders
CV mode = Constant Voltage. Selected when operating with Arcfeed CV-mode
9
FastMig KMS 400 AS / © Kemppi Oy / 1021

Related product manuals