OPERATION OF COOLING FAN4.3
In FastMig KMS 400 AS power source there is two simultaneously operating fans.
The fan is started for a moment when main switch is placed into position I.•
The fan will start during welding as the machine heats up and it will run for 1 to 10 •
minutes after the welding has stopped.
BASIC TROUBLESHOOTING5.
NOTE! The problems listed and the possible causes are not denitive, but serve to suggest some
standard and typical situations that may present during normal environmental use when using
the MIG/MAG process with FastMig.
Problem Check the following
Machine won’t work? Check mains plug is connected•
Check mains power distribution is switched on•
Check the mains fuse and or circuit breaker•
Check power source 0/I switch is ON•
Check interconnection cable set and connectors between the power source and •
wire feed unit are correctly fastened. See the manual schematic
Check earth return lead is connected•
Check function panels are switched on – Orange buttons top left, long press.•
Dirty, poor quality weld? Check shielding gas supply•
Check and set gas ow rate•
Check gas type for application•
Check gun/electrode polarity. Example: Fe solid ller wire: Earth return should be •
connected to the – pole, wire feed unit to the + pole connector
Check correct welding curve selected•
Check correct Channel (job) number selected on PF65 function panel •
Check power supply – Phase down?•
Variable welding performance? Check wire feed mechanism is correctly adjusted•
Check correct drive rolls are tted•
Check wire spool overrun tension is correctly adjusted•
Check gun liner is not blocked. Replace if necessary•
Check correct gun liner is tted for the ller wire size and type•
Check contact tip for size, type and wear•
Check gun is not over heating in application •
Check cable connections and earth return clamp•
Check welding parameter settings.•
Filler wire won’t feed? Check wire feed mechanism. Pressure arms are closed? Close and adjust•
Check welding gun switch function.•
Check euro gun collar is correctly fastened to euro block•
Check gun liner is not blocked•
Check contact tip, size, type, wear•
Check and try alternative gun.•
High spatter volume? Check welding parameter values•
Check inductance/Dynamics values•
•Checkcablecompensationvalueiflongcablesaretted•
Check gas type and ow•
Check welding polarity – cable connections•
Check ller material selection•
Check correct welding curve selected•
Check correct Channel (job) number selection •
Check ller wire delivery system•
Check power supply – 3 x phase present? •
NOTE! Many of these checks may be carried out by the operator. However certain checks relating to
mains power must be completed by an authorised trained electrician.