MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Operating manual - EN
To adjust parameters:
1. Go to the Start & stop sequence view.
2. Turn the control knob (1) to browse through the parameters.
3. Select a parameter for adjusting by pressing the control knob button (1).
4. Adjust the parameter by turning the control knob (1).
5. Close the parameter setting by pressing the control knob (1).
Adjustable parameters in all welding modes:
Parameter Value Note
Trigger logic
2T / 4T / 4T LOG / 4T LOG + Minilog (Default =
2T)
Welding mode
Continuous / Spot / MicroTack
Welding current
Default = 50 A
Ignition mode
Lift TIG / High frequency (HF) ignition
Adjustable parameters in continuous welding:
Parameter Value Note
Pre gas
0.0 s ... 10.0 s, Auto, 0.1 s step (Default =
Auto)
Search arc
OFF / 5 % ... 90 %, step 1 % (Default = OFF)
Upslope
OFF / 0.1 s ... 5.0 s, 0.1 s step (Default = 0.0 s)
Hot start level
-80 % ... 100 %, 1 % step (Default = OFF, 0
%)
Hot start time
0.1 s ... 5.0 s, 0.1 s step (Default = 1.2 s) This is not available with 4T trigger logic.
Minilog level
-99 % ... 125 %, 1 % step (Default = OFF, 0
%)
© Kemppi
42
1920900 / 2052

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi MasterTig 335ACDC and is the answer not in the manual?

Kemppi MasterTig 335ACDC Specifications

General IconGeneral
BrandKemppi
ModelMasterTig 335ACDC
CategoryWelding System
LanguageEnglish

Related product manuals