MinarcMig™ Adaptive 150
18 © Kemppi Oy 0550
EN
PROBLEM CAUSE
The wire does not move
or wire feed entangles
Feed rolls, wire conduit or contact tips are
defective
Check that feed rolls are not too tight or too
loose
Check that the feed roll groove is not too
worn
Check that the wire conduit is not blocked
Check that there are no spatters on the
conduit tip and that the hole is not cramped
or worn loose
Main switch indicator
light does not switch on
The machine has no supply voltage
Check supply voltage fuses
Check supply voltage cable and plug
Machine welds badly Welding outcome is influenced by several
factors
Tarkista, että langansyöttö on tasaista
Check the trimming settings of welding
power control and arc length
Check that the earthing clamp is fixed
properly, fixing point is clean, and both
cable and its connections are undamaged
Check the flow of shielding gas from the tip
of the welding gun
Supply voltage is uneven, too low or too
high
Over-heating indicator
light switches on
The machine has over-heated
Check that cooling air can flow without
obstructions
Machine’s volume-capacity ratio has been
exceeded; wait for the indicator light to
switch off
The supply voltage is too low or too high
5. TROUBLESHOOTING
If the machine’s malfunction can not be corrected with these measures, contact
the KEMPPI maintenance service.