19
© Kemppi Oy / 1736
EN
3.3.8 Extra functions button (8)
XF 37
W007241
CH REMOTE
CHANNEL
PANEL
4T
2T
Short press: Selects Crater ll or Hot start function.
Long press: Turns MMA/CC/CV mode ON/OFF.
3.3.9 Remote Selection Button (9)
W007241
PANEL
Short press: Toggles the control between the control panel, gun remote control unit and
hand-held remote control unit.
NOTE! If RemoteAutoRecog setting is ON in X 37 control panel, you can select only those remote
controls, which can be found in the system.
Long press: Turns the memory channel remote selection ON/OFF. This is available only if you
have selected either gun remote control unit or hand-held remote control unit. Not available
in MMA/CC/CV mode.
3.3.10 Power control knob (10)
XF 37
W007241
CH REMOTE
CHANNEL
PANEL
4T
2T
This control knob adjusts
• wire feed speed or power in MIG/MAG processes (before or during welding)
• MMA/CC current level (before or during welding)
• selected parameter values.
3.3.11 Arc length and voltage control knob (11)
XF 37
W007241
CH REMOTE
CHANNEL
PANEL
4T
2T
This control knob adjusts the arc length, voltage or selected parameter values before or
during welding.