Err1
Power source is not calibrated or calibration data cannot be read
Restart power source
if the problem continues after multiple startups contact Kemppi service representative
Err 3
Overvoltage in the mains supply
Check the mains voltage
Err 4
Power source is overheated
Do not shut down, let the fans cool the machine.
Check ventilation.
If cooling fans are not running, contact Kemppi service representative.
Err 5
Mains power supply voltage is too low or one of the phases is missing or auxiliary supply is
faulty
Check the mains supply and auxiliary supply and contact Kemppi service representative if
necessary.
Err 8
FPGA is not congured
Restart the power source.
If the error persists, contact Kemppi service representative
Err 9
Loose cable connections
Check the voltage sensing cable, measurement cable and earth return cable.
Err 10
Illegal process
The welding process is not available in this machine.
Err 12
Plus and minus DIX cable connectors are in contact
Check welding cables
Err 27
Error in the liquid-cooling unit
Check the connections in the cooling unit.
Err 42 or Err 43
Over current in wire feeder motor
Check that the welding gun and consumable parts are properly mounted
Err 45
Gas guard alert
Check the shielding gas, gas guard and all connections.
Err 50
The function is not activated in this machine
If you need this function, order a licence for it from a Kemppi representative.
WiseDemo period might be over.
Err 51
Rear feed roll may be loose
Check that the feed rolls are properly tightened.
Err 52
Front feed roll may be loose
Check that the feed rolls are properly tightened
Err 62
Power source is not connected or not identied by the wire feeder
Check the intermediate cable and its connections.
Err 81
Welding program is not found
If you need the welding program, order a licence for it from Kemppi representative.
MEM ERR & NO DAT
Machine cannot complete read or write functions on the wire feeder memory card
Check the cables and connections.
Contact Kemppi service representative.
NO BUS
Control panel cannot establish a connection to the CAN bus
Check the at cables and the control panels.
Contact Kemppi service representative.
SUB ERR
WF-number change error
Connect only one wire feeder to system and try again.
NOTE! Many of these checks may be carried out by the operator. However certain checks relating to
mains power must be completed by an authorised trained electrician.
NOTE! In the case of an error code other than the listed above, contact Kemppi service
representative.