44 EOC-BA-e-1610
AUTO*
For automatic add-up see chap. 7.10.
This function is used to issue and add individual
weighing values automatically to the summation
memory on unloading of weighing scale.
ASK
Remote control instructions
wirel
Not documented
BAUd
Available Baudrate: 600, 1200, 2400, 4800, 9600*
Pr
7E1
7 bits, even parity
7o1
7 bits, odd parity
8n1*
8 bits, no parity
PtYPE
tPUP*
Standard printer setting
KCP
Not documented
LAb
Lab x
Data output format
Prt
Prt x
LAnG
eng*
Standard settings English
chn
P3 CAL
Configuration data
CoUnt
Display internal resolution
dECL
Position of the decimal point
dUAL
Setting balance type, capacity (Max) and readability (d)
off
Single-range balance
r1 inC
Readability
r1 CAP
Capacity
on
Dual range balance
r1 inc
Readability 1st weighing range
r1 cap
Capacity 1st weighing range
r1 inc
Readability 2nd weighing range
r1 cap
Capacity 2nd weighing range
CAL
noLin
Adjustment, see chap. 6.7
LinEr
For linearisation see chapter 6.9
Grb
not documented
P4 otH
LoCK
on
Keyboard lock enabled, see chap. 7.13
oFF*
Keyboard lock disabled
Anm
on
Animal weighing enabled, see chap. 7.12
oFF*
Animal weighing disabled