FTC-BA-e-0720
21
Counting
User manual ME-Nr.22017145 01/07
3.7.1 Counting with a reference scale
Prerequisite
The connected second scale is configured as reference scale.
1. Place the reference parts on the reference scale and press or .
The scale determines the average piece weight and changes to the display in
pieces (PCS).
2. Place the parts to be counted on the first scale.
The total quantity is displayed.
Note
• If tOtAL-Ct -> bULK is set in the menu, only the number of pieces on the bulk
scale is displayed.
• If tOtAL-Ct -> bOtH is set in the menu, the reference quantity is added to the
bulk quantity.
3.7.2 Counting with a bulk scale
Prerequisite
The connected second scale is configured as bulk scale.
1. Place the reference parts on the first scale and press or .
The scale determines the average piece weight and changes to the display in
pieces (PCS).
2. Place the parts to be counted on the bulk scale.
The total quantity is displayed.
Note
• If tOtAL-Ct -> bULK is set in the menu, only the number of pieces on the bulk
scale is displayed on the bulk scale.
• If tOtAL-Ct -> bOtH is set in the menu, the reference quantity is added to the
bulk quantity.