4.6.6 DEF.PRN – configuring templates
OUT 1 ... 4
OFF
StAbLE
bEL.MIN
AbV.MIN
UNdErLd
OVErLd
StAr
ANALOG Configuration of the analog second scale interface
Mode Operating mode of the second scale
rEF
• Second scale can only be used to determine the average piece weight
bULK
• Second scale can only be used as bulk scale
AuXILIA
• No difference between reference and bulk scale, all functions available on the
scale selected
BYPASS
• Second scale interface not assigned
tEMPLt1/tEMPLt2 Selecting Template 1 or Template 2
LINE 1 ... 20 Select line
NOt.USEd
• Line not used
HEAdEr
• Line as header. The contents of the header must be defined via an interface com-
mand, see Section 5.1.
SCALE.NO
• Scale number
GROSS
• Gross weight
tArE
• Tare weight
nEt
• Net weight
APW
• Average piece weight
rEF Ct
• Reference quantity
PCS
• Pieces
StARLN
• Line with ***
CrLF
• Line feed (blank line)
F FEEd
• Page feed