PARAMETERS DESCRIPTION
DEFAULT
CONFIGURATION
MIN MAX UNIT
1
EL.F.
Electric brake
0 = disabled
1 = enabled
0 0 100
x 0.01s
(steps of 5)
2
SP.h.
PHOTO1 response on start-up from closed
0 = PHOTO1 check
1 = the gate also opens if PHOTO1 is engaged
1 0 1
3
Ph.2.
PHOTO2 response
0 = Enabled in opening and closing OP/CL
1 = Enabled only in opening OP
0 0 1
4
tP.h.
Photo device test
0 = disabled
1 = PHOTO1 enabled
2 = PHOTO1 enabled
3 = PHOTO1 and PHOTO2 enabled
0 0 3
5
ed.M.
Type of edge
0 = contact (NC)
1 = resistive (82k)
0 0 1
6
iE.D.
Edge intervention mode
0 = intervenes only on closing with inversion of direction
1 = stops automation (on opening and closing) and releases
the obstacle (short inversion)
0 0 1
7
tE.D.
Edge test
0 = disabled
1 = enabled
0 0 1
8
LP.o.
Pedestrian opening 30 0 100
% (steps
of 1)
9
TP.C.
Automatic reclosing time from pedestrian (0 = disabled) 20 0 900 s
10
FP.r.
Flashing light output conguration
0 = Steady
1 = Flashing
1 0 1
11
tP.r.
Pre-ash time
(0 = disabled)
0 0 10 s
12
FC.Y.
Courtesy light conguration
0 = At end of manoeuvre, lit for time TCY
1 = Lit if gate is not closed + duration TCY
2 = Lit if courtesy light timer (TCY) not elapsed
3 = Gate open indicator on/off
4 = Gate open indicator proportional ashing
0 0 4
13
tC.Y.
Courtesy light duration 0 0 900
s (steps
of 10s)
14
dE.A.
Hold-to-run
0 = disabled
1 = enabled
0 0 1
15
se.r.
Cycle threshold for assistance request. On reaching the set
threshold the subsequent cycles will be performed with
quick ashing (only if FPr is active).
(0 = disabled)
0 0 100
x 1000
cycles
16
se.f.
Enabled in continuous ashing mode for assistance requests
(function only enabled when gate is closed).
0 = disabled
1 = enabled
0 0 1
17
HA.o.
Water hammer on opening
0 = disabled
0 0 100 *100ms
18
HA.c.
Water hammer on closing
0 = disabled
0 0 100 *100ms
19
mp.r.
Interval for maintaining hydraulic motor pressure
0 = disabled
from 1 to 480 enabled as follows: 1 = 1 min. ON and 1 min
OFF, 2 = 1 min. ON and 2 min. OFF, ...
0 0 480 minutes
20
de.f.
Reset to default values
and hold it down). A countdown should now appear: d80,d79...,d01