Keyscan Inc. Technical Guide (PC109x - 04.15)
107
Figure 73 HID iClass R90 Long Range Reader
Shield not connected.
Isolate with electrical tape.
to separate
power supply
(3 Amp supply
recommended)
3 pairs shielded
18 AWG
500 ft (152.4 m)
maximum
P2-1 +DC
P2-2 Ground/Shield
P2-3 Green LED Control
P1-7 Data 1
P1-6 Data 0
P1-5 Ground
Shield
ACU Ground
Lug
White
Green
Red +
Black 2
Brown
Black 1
Black -
Black 2
Black 1
Green
White
Red
Brown
Terminal block on R90 reader
R90 Current Draw
12 VDC 1300 mA
24 VDC 700 mA
Reader terminal on control board
LED D1
WHT
D0
GRN
PWR
RED
GND
BLK
C1
(BEEP)
KI-00501E-03-13