Language Dictionary - 4
41
Table 4-1. Subsystem Commands Syntax (continued)
OUTPut
[:STATe] <bool> [,NORelay]
Enables/disables the dc source output
:DFI
[:STATe] <bool>
Enable/disable DFI output
:SOURce <source>
Selects event source (QUES | OPER | ESB | RQS | OFF)
:PON
:STATe <state>
Set power-on state (*RST | RCL0)
:PROTection
:CLEar
Reset latched protection
:DELay <n>
Delay after programming/before protection
:RELay
[:STATe] <bool>
Opens/closes the external relay contacts
:POLarity <polarity>
Sets the external relay polarity (NORM | REV)
:RI
:MODE <mode>
Sets remote inhibit input (LATC | LIVE | OFF)
SENSe
:CURRent
[:DC]
RANGe [:UPPer] <n>
Selects the high current measurement range
:DETector <detector>
Selects the current measurement detector (ACDC | DC)
:FUNCtion <function>
Configures the measurement sensor ("VOLT" | "CURR")
:SWEep
:OFFSet
:POINts <n>
Defines the offset in the data sweep
:POINts <n>
Define the number of data points in a sweep
:TINTerval <n>
Sets the digitizer sample spacing
:WINDow [:TYPE] <type>
Sets the measurement window function (HANN | RECT)
[SOURce:]
CURRent
[:LEVel]
[:IMMediate][:AMPLitude] <n>
Sets the output current level
:TRIGgered [:AMPLitude] <n>
Sets the triggered output current level
:PROTection
:STATe <bool>
Enable/Disable current limit protection
DIGital
:DATA [:VALue] <n>
Sets and reads the digital control port
:FUNCtion <function>
Configures digital control port (RIDF | DIG)
VOLTage
[:LEVel]
[:IMMediate][:AMPLitude] <n>
Sets the dc voltage level
:TRIGgered [:AMPLitude] <n>
Sets the transient voltage level
:ALC
:BANDwidth? | :BWIDth?
Returns setting of output mode switch
:PROTection [:LEVel] <n>
Sets the overvoltage protection threshold

Table of Contents