Keysight Technologies E364xA Series Specifications

General IconGeneral
Operating Temperature Range0 to 50 °C
Storage Temperature Range-40 to 70 °C
Power Rating100 W
Number of Outputs1 or 2 (depending on model)
DisplayLED
InterfaceGPIB
Programming Accuracy Current0.2% + 5 mA
Ripple & Noise (20 Hz to 20 MHz)1 mVrms
Load Regulation Voltage0.01% + 2 mV
Line Regulation0.01% + 2 mV
Dimensions (W x H x D)8.4 in

Summary

Notices and Safety Information

Safety Information

Explains CAUTION and WARNING notices for safe operation.

Safety Symbols and Considerations

General Safety Precautions for Use

Provides essential safety rules to follow before and during instrument use.

Safety and EMC Requirements

Getting Started

Preparing the Power Supply for First Use

Step-by-step guide for initial power supply setup, connection, and self-test.

Product at a Glance: Front Panel

Identifies and describes the functions of the front panel keys and display.

Setting Voltage and Current Limits

Explains how to set voltage and current limit values from the front panel.

Operation and Features

Constant Voltage (CV) Operation

Step-by-step guide for setting up and operating in constant voltage mode.

Constant Current (CC) Operation

Step-by-step guide for setting up and operating in constant current mode.

Configuring the Remote Interface (GPIB;RS-232)

Details on setting up GPIB and RS-232 interfaces for remote control.

Programming Overvoltage Protection (OVP)

Instructions for setting, checking, and clearing OVP trip levels.

Remote Interface Reference

Output Setting and Operation Commands

Details commands for setting output voltage, current, and ranges.

Error Messages Guide

Execution Error Messages

Lists and explains errors related to command execution and syntax.

Self-Test Error Messages

Details error codes indicating failures during self-test procedures.

Calibration Error Messages

Lists and explains error messages that may occur during calibration.

Characteristics and Specifications

Electrical Specifications

Detailed electrical parameters including voltage, current, accuracy, and noise.

Service and Maintenance Guide

Electrostatic Discharge (ESD) Precautions

Guidelines to prevent ESD damage when servicing electronic devices.

Troubleshooting Common Failures

Provides a checklist of common failures and potential solutions.

Self-Test Procedures

Instructions for performing power-on and complete self-tests.

Recommended Test Equipment

Lists necessary equipment for performance verification and adjustment procedures.

Calibration Reference

Information on unsecuring the power supply for calibration and calibration services.

General Calibration or Adjustment Procedure

Step-by-step guide for performing front panel voltage, OVP, and current calibration.